Mahsulot profili 8F MPO - MPO erkak magistral kabeli OM4 zamonaviy ma'lumotlar markazlari va tolali tarmoqlarning rivojlanayotgan talablarini qondirish uchun tiklanadigan ishonchli echimdir. Ushbu magistral kabel izchil ishlash va ishonchlilikni ta'minlash uchun diqqat bilan ishlab chiqilgan va qat'iy sinovdan o'tgan. Jihozlangan ...
So'rov yuborish

 

Mahsulot profili

 

Biz MTP / MPO magistral kabellarini 12 - Core 4 versiyalarini taklif etamiz. 150 metr masofalardan foydalanilganda, 8F MPO-MPO erkak magistral kabel kabelli OM4 40 gbit / s maksimal pul o'tkazmasiga erishishi mumkin. Ma'lumot tezligi 100 Gbit / s bo'lsa, maksimal uzatish masofasi 100 m. Ushbu MTP / MPO magistral kabellari bazaviy-8 tizimining orqa mtasining orqa mtasiga va birinchi navbatda MTP / MPO adapter modullariga ulanish uchun ishlatiladi. Bu ikkala uchida MTP erkak ulagichlariga ega va shu bilan QSFP + modullar uchun mos emas.

 

Mahsulot xususiyatlari

 

Jismoniy xususiyatlar Parametr
Tola samara 8/12/16/24/48 tolalar / odat
Tola rejimi Sm (OS2) / mm (OM3 / OM4 / OM5)
Ulagich turi AQSh konspori mtp ayol / erkak; Mpo ayol / erkak
Chidamlilik A / B / C ni kiriting
Kabel ko'ylagi PVC / LSZH / OFNP
Ko'ylagi rangi Sariq / Aqua / Magenta / ohak yashil / odat
Kabel diametri (mm) 3
Minimal Bendlar radius 7.5
Tola va yuklash uzunligi Odatlangan

 

     
Optik xususiyatlari Parametr
Qo'shish yo'qotish (DB) Standart yo'qotish Kam etkazish Ultra kam yo'qotish
0,7 dan kam yoki unga teng Sm 0,35, mm dan kam yoki unga teng 0,25 dan kam yoki unga teng
Qaytish (DB) Sm 60 dan katta yoki unga teng, mm 20 dan katta yoki unga teng
To'lqin uzunligi (nm) Sm 1310/1550, mm 850/1300
Keskinlik kuchi (n) Uzoq muddatli Qisqa muddatga
70N 220N
Harorat harorati (daraja) -40 ~ +85
Saqlash harorati (daraja) -20 ~ +70

 

 

Mahsulot xususiyatlari

 

Polarity Precision
Parramud aniqlik

Kabel A yoki C tugmachasini A yoki C tugmachasini ({2}} tugmachasini ishga tushiradi. MPO - MPO konfiguratsiyasi turli xil ulanish ehtiyojlarini qondirish uchun moslashuvchanlikni qo'shadi.

Push-Pull Design
Oqimli o'rnatish va xatolarni o'chirish

O'rnatish qulayligi asosiy ko'rib chiqishdir. Integratsiyalashgan bosish - torting, ayniqsa yuqori - yuqori - zichlikdagi belgilar. Ushbu dizaynni nafaqat o'rnatishni tezlashtiradi, balki ishonchli tarmoqqa hissa qo'shgan xatolar uchun imkoniyatlarni minimallashtiradi.

Optimized MPO Connector
Optimallashtirilgan ishlash

Bendlar - befarq tolali texnologiyani, kabel kengayish moslashuvchanligini ta'minlaydi. MPO ulagichlari, 0,25db 0,25dbning minimal hajmini yo'qotish, yuqori - tolasidagi barqarorlik va ishonchlilikni ta'minlash.

Standard Compliant
Sanoat standartlariga javob berish

IEC 61754 {{4} {{4} {{4} {}} {}} {}} -, Telcordia GR-1435- yadrosi kabi xalqaro standartlarga rioya qilish Kabel alangali ramzli ko'ylak bilan jihozlangan, turli muhitlarda xavfsizlikni kuchaytiradi va xavfsizlik talablariga javob beradigan.

 

Arizalar

 

High Density Data Center

Yuqori zichlikdagi ma'lumotlar markazi

Backbone Network

Backboon tarmog'i

Communication Rooms

Aloqa xonalari

 

Ishlab chiqarish rasmlari

 

Optiko muhandislarning kuchli muhandislari, logotiplar, logotiplar, ulagichlar, yadrolar soniga va boshqa maxsus talablarga ega bo'lishi mumkin.

 

Maxsus talablaringizni sozlash uchun biz bilan bog'laning.

 

8 mpo om4

 

Ulanish echimlari

40 g magistral kababl eritmasi

 

1. Core kabelli eritmasi:
a. Asosiy ulanish uskunalari
Yuqori - ijro etish tugmachasi va a bilan jihozlash40 g baza - sr4 qSfp {{3} {+ 850 NM 150M Optik tracew Modul40 Gb / s ga erishish.

 

b. Tolaning ulanish usuli
Foydalanish
8F MPO - MPO ayol magistral kable OM4 gaUskunani ulang.

 

 

v. Kabel Kabel boshqarmasi:
Amalga oshirmoqYuqori - zichlik 1u taglik o'rnatish moslamasisokin tortmasi bilan kabellarni tashkil qilish uchun, tartibsizlikning oldini olish.

 

2. Ulanishga kirish uchun yadro
Foydalanish8F MPO mpo ayol magistral kabelli kabel simlariyadro va kirish nuqtalarini ulash.

 

3. Kabellash eritmasi
Yadroli kabelli echim bilan bir xil.

 

Sertifikatlar

 

CE-Patchcord

Yamoq

CPR

Dog '

ISO

Iso

RoHS-Patchcord-PLC

Rohs

 

Uchinchi -} partiyasi laboratoriyasidan ishonchlilik testlari

 

Coupling Test

Bouning testi

Drop Test

Tomchi sinov

Durability Test

Qulaylik sinovi

High-Constant Temperature and Humidity Test

Yuqori - doimiy harorat va namlik sinovi

High-Low Temperature Test

Yuqori - past harorat sinovi

Loss Test

Yo'qotish sinovi

Micro Cross Section Inspection Test

Mikro kesishish bo'limini tekshirish testi

Resistant to Repeated Bending Test

Takroriy kutish sinoviga chidamli

 

Single Vertical Burning Test

Bitta vertikal yonish testi

Temperature Change Test

Harorat o'zgarishi testi

UV Test

UB testi

 

 

Yetkazib berish (7-15 kun)

 

various delivery services

 

Optiko bir qator ishonchli etkazib berish variantlarini, shu jumladan havo yuklarini, dengiz yukini, quruqlik yukini, Fedex, DHL va UPS kabi ishonchli provayderlar orqali etkazib berishni taklif etadi. Sizga tezlik, - narxi yoki moslashuvchanligi kerakmi, optiko sizni qamrab oldi. O'zingizning mahsulotlaringizni xavfsiz va vaqtida olish kerak bo'lgan mahsulotlarni olish uchun optiko.

 

 
TSS
 

 

Savol: MPO - MPO kabeli uchun mavjud bo'lgan tolali variantlar qanday?

Javob: MPO magistral kabeli turli xil ulanish ehtiyojlarini qondirish uchun turli xil tolalarni hisoblash variantlarida mavjud. Mijozlar 8 ta toladan, 12 tola, 72 tola, 96 tola, 96 tola, 96 tola, 92 tola va ulanishni ko'paytirishni talab qiladigan 8 tolasi va 144 tola kabi moddiy talablarga javob beradigan konfiguratsiyalardan birini tanlashlari mumkin. Kichik - miqdori yoki katta - miqyosli, balandlikdagi - zichlik optik muhit, optiko turli xil tolalarni hisoblash talablarini qondirish uchun moslashuvchanlikni ta'minlaydi.
 

Savol: 8F MPO - MPO erkak magistral kabur demociM4 tarmoq arxitekturalariga mos keladimi?

Javob: Ha, 8F MPO - MPO erkak magistral kabel OM4 turli tarmoq arxitekturalariga nisbatan ko'p qirrali va mos keladi. Uning mosligi - tolali tolalarning optik tolalari bilan ajralib turadi, uni turli xil tarmoq sozlamalarida joylashtirish uchun mos keladi. Raqamli xochda - ulanadimi, optik orqa varaqlarni yoki kanallarni saqlash muassasalari, ushbu kabel ishonchli va samarali ulanishni ta'minlash uchun muhandisdir.
 

Savol: Men kabelni maxsus konfiguratsiya va uzunliklarga sozlashim mumkinmi?

J Albatta,: albatta! Professional ishlab chiqaruvchi sifatida optiko har qanday aniq konfiguratsiya va uzunlik talablarini qondirish uchun sozlash variantlarini taklif qiladi. Uzunliklar, kabel bosib chiqarish, ulagich turi, tola turi va boshqalar bundan mustasno, shuningdek, siz sales@fiberopticom.com da siz bilan bog'lanishingiz mumkin.

 

 

 

 

 

 

 

 

Issiq teglar: 8F MPO - MPO erkak magistral kabel OM4, Xitoy, ishlab chiqaruvchilar, etkazib beruvchilar, zavod, ulgurji, ulgurji savdo

 

Jismoniy xususiyatlar Parametr
Tola samara 8/12/16/24/48 tolalar / odat
Tola rejimi Sm (OS2) / mm (OM3 / OM4 / OM5)
Ulagich turi AQSh konspori mtp ayol / erkak; Mpo ayol / erkak
Chidamlilik A / B / C ni kiriting
Kabel ko'ylagi PVC / LSZH / OFNP
Ko'ylagi rangi Sariq / Aqua / Magenta / ohak yashil / odat
Kabel diametri (mm) 3
Minimal Bendlar radius 7.5
Tola va yuklash uzunligi Odatlangan

 

     
Optik xususiyatlari Parametr
Qo'shish yo'qotish (DB) Standart yo'qotish Kam etkazish Ultra kam yo'qotish
0,7 dan kam yoki unga teng Sm 0,35, mm dan kam yoki unga teng 0,25 dan kam yoki unga teng
Qaytish (DB) Sm 60 dan katta yoki unga teng, mm 20 dan katta yoki unga teng
To'lqin uzunligi (nm) Sm 1310/1550, mm 850/1300
Keskinlik kuchi (n) Uzoq muddatli Qisqa muddatga
70N 220N
Harorat harorati (daraja) -40 ~ +85
Saqlash harorati (daraja) -20 ~ +70